TECHNOLOGY / 02
Infrared thermography: a heat picture speaks only when conditions are right
An infrared camera shows heat you cannot see: hotspots on solar panels, debonded facade tiles, missing insulation, overheating electrical joints. But the colours are not always the temperature. Let’s look honestly at the physics and the timing.
On this page
What a thermal camera actually measures
Everything with a temperature emits infrared. Most drone thermal cameras sense long-wave infrared (LWIR), roughly 8–14 µm, with an uncooled microbolometer. The camera receives radiant energy, not temperature; temperature is a conversion.
To get a correct temperature you must give the camera at least emissivity, reflected temperature, and distance and humidity. In inspection, what usually matters more than the absolute value is the difference from the surroundings (ΔT). Comparing surfaces of the same material and orientation cancels much of the emissivity and reflection error.
The emissivity and reflection trap
| Surface | Typical emissivity | Caution |
|---|---|---|
| Concrete, mortar, tile | High (around 0.9) | Relatively easy; changes when wet or dirty |
| Painted surfaces (any colour) | High (around 0.9) | Visible colour and IR emissivity are unrelated |
| Glass (including PV cover glass) | Fairly high but mirror-like | Reflects sky, sun, even the drone |
| Rusted or oxidised metal | Medium to high | Patchy; varies from spot to spot |
| Polished metal, new aluminium, galvanising | Very low | Temperature barely measurable; reflections dominate |
Emissivity also depends on viewing angle: the more grazing the view, the lower the emissivity and the stronger the reflection. A facade shot from a rooftop or a panel imaged obliquely may not be comparable with a square-on shot. Also, a clear sky is very cold in the infrared; when glass or metal reflects it, the surface looks colder than it is.
Solar loading and timing: when to fly
Half the success of thermography is timing. Thermal contrast appears only while heat is flowing: when a facade is heated by the sun or cooling down, when there is an indoor–outdoor difference for insulation, when current flows in electrical equipment.
- Time by orientation: each face gets sun at different hours — east in the morning, south around midday, west in the afternoon. North faces get little sun and show weak contrast.
- Weather: rain the day before, strong wind or weak overcast sun all shrink the contrast.
- Season: for missing insulation, fly on winter nights or early mornings with a large indoor–outdoor difference and no residual solar effect.
- Load: electrical faults heat more at higher current. Declaring “no anomaly” at light load is risky.
For facade surveys, planning infrared facade capture around sunlight, reflection and quality checks (Airffic Flight Institute) sets out the steps.
Reading thermography by application
| Target | What shows | Conditions | Main traps |
|---|---|---|---|
| Solar PV | Hotspots from cracked cells, failed bypass diodes, soiling or shade; disconnected strings | Operating, strong and stable irradiance (an IEA PVPS 2018 review recommends above 600 W/m²) | Sun and sky reflections, viewing angle |
| Facade tiles & render | Debonding (warm by day, cool by night) | Time matched to orientation, sunny and calm days | Colour and material differences, reflections, joints, window frames |
| Insulation & airtightness | Missing insulation, thermal bridges, air leaks | Winter nights or early mornings with large indoor–outdoor difference | Residual solar heat, furniture and heaters inside |
| Electrical gear on power lines and in plants | Heating from loose or corroded joints | High load; compare phases with each other | Low metal emissivity, wind cooling, strong EM fields |
| Piping & tanks | Damaged insulation, liquid levels, blockages | When contents and ambient differ | Reflections from metal cladding |
Under Japan’s periodic building reporting, full-surface hammer sounding of facade tiles is required in some cases. A January 2022 amendment of the relevant notice explicitly allowed infrared surveys with accuracy equal to or better than sounding, including those by drone. The condition is that the survey actually achieves that accuracy. See condominiums for how this is used.
For electrical equipment the basic method is ΔT between phases under the same conditions, not absolute temperature. If one of three phases has a hot joint, that is the clue. Electromagnetic fields near lines are strong, so the aircraft needs precautions too. Strong electromagnetic fields
Radiometric versus non-radiometric
Thermal cameras are either radiometric, storing temperature data per pixel, or non-radiometric, storing only a coloured picture. For inspection records, radiometric is the only real choice.
| Radiometric | Non-radiometric | |
|---|---|---|
| What is stored | Temperature (or radiance) per pixel plus capture parameters | An image painted with a palette |
| Afterwards | Recompute with new emissivity, reflected temperature or range | Colour range fixed at capture |
| Suited to | Recording ΔT, reporting, year-on-year comparison | Spotting in flight, search, visual aid |
| Caution | Many specify about ±2 °C or ±2%; parameters must be entered | Same colour ≠ same temperature (auto-ranging shifts the scale) |
Thermal sensors have few pixels (640×512 is common). With a 12 µm pitch, 640 pixels and 13.5 mm focal length, GSD = sensor width × distance ÷ (focal length × pixels) gives about 2.7 cm at 30 m. A rule often quoted is to put several pixels (around 3×3) on anything you want to measure; a small joint imaged from far away is averaged with its surroundings and reads low. The GSD logic is the same as in the visible imaging chapter.
Always store a matching visible image with each thermal image, plus air temperature, humidity, irradiance, wind and load at capture. A thermal image without conditions is unreadable a few years later.
What thermography cannot do
- Through glass or polished metal: LWIR does not pass through glass; you cannot see indoors through windows. Polished metal barely reads.
- Depth: only surface temperature is visible. Deep delaminations and internal voids barely change it.
- Bad conditions: overcast, after rain, strong wind or during the daily crossover, anomalies may not show at all.
- Root cause: you learn that something is hot, not why. Hotspot causes are confirmed with IV-curve tests or on-site checks.
- Proof of absence: not seeing an anomaly does not prove there is none.
Our view of 2035
By 2035, drones will likely pick the best time to fly from weather forecasts and solar geometry — south faces at midday, west faces in the afternoon — while emissivity and reflected temperature are assigned per surface from visible images and the 3D model. Thermal images line up per member and per year, and only changes in ΔT reach the inspector. This is the editors’ view, but the direction is clear.
The physics will not change: when heat is not flowing, nothing shows. Record the conditions and fly when they are right. That unglamorous discipline will remain at the heart of thermal inspection.
Check the evidence
Rules, figures and cases cite the sources below. Future scenarios and design proposals are the editors’ own view.
- IEC TS 62446-3:2017 Photovoltaic (PV) systems – Part 3: Photovoltaic modules and plants – Outdoor infrared thermographyInternational Electrotechnical Commission · Abstract read
- IEA PVPS Task 13: Review on Infrared and Electroluminescence Imaging for PV Field Applications (2018)IEA Photovoltaic Power Systems Programme · Full text read
- MLIT: Survey of facade tiles under the periodic reporting systemMLIT Housing Bureau · Full text read
- MLIT: Flight rules for unmanned aircraftMLIT Civil Aviation Bureau · Full text read
Sources checked: 2026-10-22